Ordering Code for Railway Fiber Optic Cables (RAILOPTICS Series)
Central Loose Tube Cable
RO/A-CL-B-C-D-E-F-G-H-I-J-K
A: Cable Category
K209A/B: Railway Fiber Optic Cables
2328: SNCF CT2328 / SNCT CT 2329
2513: SNCF CT2513-99 / SNCT CT 2513-99
2242: SNCF CT2242.6.1
B: Loose tube diameter
A=2.1mm, B=2.5mm
C: Fiber type
0=Fiber and copper conductors in cable
4=50/125 multi-mode fi ber (OM3) per ITU-T G.651
5=50/125 multi-mode fi ber (OM2) per ITU-T G.651
6=62.5/125 multi-mode fi ber (OM1) per ITU-T G.651
7=NZDS SM fi ber per ITU-T G.656.
8=NZDS SM fi ber per ITU-T G.655.
9=Standard SM fi ber per ITU-T G.652.D
Ended with R=Ribbon type fiber ( Ex: 9R= SM fiber per G.652.D ribbon type )
D: No. of fibers: 1 to 24
E: Bedding
2Y=PE, Y=PVC, H=LSZH
F: Armour
Blank=No armour, T=Corrugated steel tape armour, W=Steel wire armour
B=Bronze armour, D=Fiber glass armour; TW= Steel tape + Steel wire armour
G: Sheath
2Y=PE, Y=PVC, H=LSZH, 11Y=PU, A=Aluminium moisture barrier
T=Anti-termite protection
H: Water-blocking options for cable core
X=No water-blocking; J= Water blocking gel in tubes;
JD=Water-blocking gel in tubes + dry water blocking in cable core interstices;
JJ= Water-blocking gel in tubes and cable core interstices.
I: Water-blocking options for cables with more than one jacket
X=No water-blocking, J= Water blocking gel between jackets;
D=Dry water-blocking between cable jackets
J: Strength member
A=Aramid yarn, AG=Aramid yarn and fi berglass yarn,
G=Fiberglass yarn
K: General options
SS=Fig-8 self-supporting
Multi Loose Tube Cable
RO/A-ML-B-C-DxE-F-G-H-IJ-K-L-M
A: Cable Category
K209A/B: Railway Fiber Optic Cables
2328: SNCF CT2328 / SNCT CT 2329
2513: SNCF CT2513-99 / SNCT CT 2513-99
2242: SNCF CT2242.6.1
B: Loose tube diameter
B=2.1mm, C=2.5mm, D=2.8mm, E=3.0mm, F=3.2mm
C: Fiber type
0=Fiber and copper conductors in cable
4=50/125 multi-mode fi ber (OM3) per ITU-T G.651
5=50/125 multi-mode fi ber (OM2) per ITU-T G.651
6=62.5/125 multi-mode fi ber (OM1) per ITU-T G.651
7=NZDS SM fi ber per ITU-T G.656.
8=NZDS SM fi ber per ITU-T G.655.
9=Standard SM fi ber per ITU-T G.652.D
Ended with R=Ribbon type fiber ( Ex: 9R= SM fiber per G.652.D ribbon type )
D: No. of tubes: 1 to 36
E: No. of fibers per tubes: 2 to 12
F: Central member
S=Solid steel, SR=Stranded steel, F=Fiber Reinforced Plastic (FRP)
G: Bedding
2Y=PE, Y=PVC, H=LSZH
H: Armour
Blank=No armour, STA=Corrugated steel tape armour, SWA=Steel wire armour
B=Bronze armour, F=Fiber glass armour; TW= Steel tape + Steel wire armour
I: Sheath
2Y=PE, Y=PVC, H=LSZH,
11Y=PU, A=Aluminium moisture barrier, T=Antitermite protection
J: Water-blocking options for cable core
X=No water-blocking; J= Water blocking gel in tubes;
JD=Water-blocking gel in tubes + dry water blocking in cable core interstices;
JJ= Water-blocking gel in tubes and cable core interstices.
K: Water-blocking options for cables with more than one jacket
X=No water-blocking, J= Water blocking gel between jackets;
D=Dry water-blocking between cable jackets;
L: Strength member
A=Aramid yarn, AG=Aramid yarn and fi berglass yarn, G=Fiberlass yarn
M: General options
SS=Fig-8 self-supporting